河南嵩瑞新型耐材有限公司

Afterburner Basics: Temperature, Residence Time and Compliance

Technical Support

1. Why activation off-gas needs an afterburner

Off-gas from a steam activation furnace looks like white vapour but is unburned fuel. Carbon reacts with water vapour to form CO and H2, so the gas carries 2–8% CO, 1–3% H2, plus tar and volatiles. Vent it directly and three problems follow: CO far above the limit, tar condensing on the fan and boiler, and odour downwind.

An afterburner converts incomplete into complete combustion; its performance depends less on size than on two numbers: combustion-zone temperature and residence time.

2. 850–1100 °C and residence time are one calculation

The auto-ignition point of CO is about 609 °C, but auto-ignition only means the reaction can start. Practice holds 850 °C long enough for CO conversion to stay above 99%; tar and VOCs need more, and below 800 °C most of them merely crack and the odour remains. 850 °C is a floor produced by temperature multiplied by time.

Residence time is effective combustion volume ÷ actual flue-gas flow. The usual error is which flow you use: at 850 °C the actual flow is 3.5–4.5 times the normal-condition figure, so using the latter gives a result four times too long — 4 s on paper, 1 s in the duct. Working ranges: 850 °C with ≥2 s; 950–1000 °C with 1–1.5 s; above 1100 °C, 0.8–1 s. Add a factor of 1.5–2 for dilution air and deposits, and hold excess air at 1.2–1.5 with 3–6% O2.

1100 °C is a design ceiling, not a physical one: refractory life drops sharply there and a 60–80 mm working lining needs repair every two to three years. Most lines hold 900–1000 °C.

3. Low temperature and short time fail differently

Low temperature is visible: outlet CO climbs from below 100 mg/m³ to 300–500 mg/m³, the stack smokes blue and smells sharp — usually low heating value from wet feedstock or low steam ratio, with firing not keeping up.

Short residence time hides. At full load CO may sit at 80 mg/m³ and look compliant; when load shifts and flow spikes, CO passes 500 mg/m³ within fifteen minutes and the monthly average is lost. No burner adjustment fixes that — enlarge the combustion volume or shave the peak.

Quench obeys the same logic: 500 °C to 200 °C within about 1 s, since 250–500 °C is the re-formation window.

4. Balancing auxiliary fuel against temperature

Sufficient heating value means no supplementary firing — CO and H2 carry the afterburner above 900 °C. Fuel is needed at start-up, low load, high moisture and low steam ratio: expect 10–30 Nm³ per tonne of carbon.

Never use heavy dilution air to protect the refractory: it lowers temperature, CO stops burning, heating value falls and more gas is needed — a self-feeding loop. Control on outlet temperature, hold a minimum gas-valve opening, alarm 50 °C below setpoint, cut the feed at 100 °C below.

5. Where the monitoring points go

Four locations: the afterburner outlet, 1–2 furnace diameters past the combustion zone, with duplex thermocouples — one to control, one to interlock; the quench outlet; the stack, for CO, NOx, particulates and O2; and ahead of the induced-draft fan, for draft.

Allow straight runs of 4 and 2 pipe diameters around each probe and heat-trace sampling lines at 120–180 °C so tar does not plug them. Plot temperature and CO on one trend: a drift then shows whether temperature fell or time was never there.

FAQ

Q: Is 850 °C enough on its own? A: No. It must be paired with ≥2 s calculated on actual volumetric flow. A hot but undersized chamber still exceeds CO limits under load swings.

Q: How do I verify residence time? A: Effective combustion volume divided by measured actual gas flow, converted to afterburner temperature — never the normal-condition or design figure.

Q: What fuel consumption should I expect? A: 10–30 Nm³ per tonne of carbon; above 40 Nm³/t means heating value is being wasted — check steam ratio and furnace sealing.

Q: Can the afterburner be dropped? A: No. It is the only stage that destroys CO and VOCs; the quench tower is needed wherever heat is recovered.

Keywords: afterburner, waste gas treatment, emission compliance, activated carbon furnace

Related News

Send Inquiry